Thursday, October 18, 2012

Optimization and other Advanced Mathematics in LaTeX

Sometimes we need to put optimization problems in the paper, and the typesetting of the optimization in LaTeX is a bit tricky.




Optimization problems in LaTeX
In optimization we want to minimize or maximize an objective function over a set of decision variables sbject to constraints. There are different ways to format optimization problems, but the preferable way is to follow an excellent book “Convex Optimization” by Stephen Boyd and Lieven Vandenberghe. A general optimization problem has the form:



The LaTeX code for this formulae is the following:

\begin{equation*}
\begin{aligned}
& \underset{x}{\text{minimize}}
& & f_0(x) \\
& \text{subject to}
& & f_i(x) \leq b_i, \; i = 1, \ldots, m.
\end{aligned}
\end{equation*}

If we want to perform quadratic programming, the notation will be the following:

The LaTeX code for it is:
   
\begin{equation*}
\begin{aligned}
& \underset{x}{\text{minimize}}
& & J(x) = \frac{1}{2} \mathbf{x}^T Q \mathbf{x} + c^T \mathbf{x} \\
& \text{subject to}
& & A\mathbf{x} \leq \mathbf b \mbox{ (inequality constraint)} \\
&
& & E\mathbf{x} = \mathbf d \mbox{ (equality constraint)}
\end{aligned}
\end{equation*}
  
Unlike the tabular environment, in which you can specify the alignment of each column, in the aligned environment, each column (separated by &) has a default alignment, which alternates between right and left-aligned. Therefore, all the odd columns are right-aligned and all the even columns are left-aligned.


Another example of the optimization problem:


and the LaTeX code:

\begin{equation*}
\begin{aligned}
& \underset{X}{\text{minimize}}
& & \mathrm{trace}(X) \\
& \text{subject to}
& & X_{ij} = M_{ij}, \; (i,j) \in \Omega, \\
&&& X \succeq 0.
\end{aligned}
\end{equation*}

Here  $X \succeq 0$ means that the matrix $X$ is positive semidefinite.

This LaTeX recepe was found here.


How to render argmax / argmin operator in LaTeX?
One can use the following expression in LaTeX:
 
\begin{equation}
\arg\max_{x}
\end{equation}

which will produce the folowing:


However, you might prefer a different way that centers x in arg max expression using \underset command:

\begin{equation}
\underset{x}{\arg\max}
\end{equation}

and the result will be:

In order to use the command, you need to add the amsmath package in the preambule:

\usepackage{amssymb,amsmath,amsfonts,latexsym,mathtext}

This idea was found here.


How to add single-sided brackets in latex?

This is some kind of dirty LaTeX hack but it works nicely:

\begin{equation}
P_\Omega(x) = \left\{\begin{array}{lll}
l_i & if & x_i<l_i\\
x_i & if & x_i\in[l_i,u_i]\\
u_i & if & x_i>u_i
\end{array}\right.
\end{equation}

and it generates what we want:

Look closely for the right. statement - the dot at the end is important! Note that to produce the single-sided brackets, you need to add empty \left. or \right.  brackets.


The trick has been taken from here: how to add single-sided brackets in latex


Sunday, September 2, 2012

Normalised histogram calculation


Normalised histogram calculations

The usual approximation for the probability density function is a histogram. The probability density function is non-negative everywhere, and its integral over the entire space is equal to one [1]. Formally, a random variable X has density f, where f is a non-negative Lebesgue-integrable function, if:

\operatornameP[a ≤ X ≤ b]=∫abf(x)\,\mathrm{d}x.


There are many ways to normalise the histogram, and some of those methods have limitations. Consider all of them.


Normalisation by sum

This solution answers the question How to have the sum of all bins equal to 1. The example of code is here:


[f,x]=hist(randn(10000,1),50);%# create histogram from a normal distribution.
g=1/sqrt(2*pi)*exp(-0.5*x.^2);%# pdf of the normal distribution

%#METHOD 1: DIVIDE BY SUM
figure(1)
bar(x,f/sum(f));hold on
plot(x,g,'r');hold off


This approximation is valid only if your bin size is small relative to the variance of your data [2]. The sum used here correspond to a simple quadrature formula, more complex ones can be used like trapz.


Normalisation by area

For a probability density function, the integral over the entire space is 1. The previous accepted answer will not give you the correct density. To get the right density, you must divide by the area. To illustrate my point, try the following example.


[f,x]=hist(randn(10000,1),50);%# create histogram from a normal distribution.
g=1/sqrt(2*pi)*exp(-0.5*x.^2);%# pdf of the normal distribution

%#METHOD 1: DIVIDE BY SUM
figure(1)
bar(x,f/sum(f));hold on
plot(x,g,'r');hold off

%#METHOD 2: DIVIDE BY AREA
figure(2)
bar(x,f/trapz(x,f));hold on
plot(x,g,'r');hold off

You can see for yourself which method agrees with the correct answer (red curve).


However, for some distributions (like Cauchy) I have found that trapz will overestimate the area, and so the pdf will change depending on the number of bins you select. In this case it is useful to do:
[N,h]=hist(q_f./theta,30000);
% there Is a large range but most of the bins will be empty
plot(h,N/(sum(N)*mean(diff(h))),'+r')

Appendix: Trapezoid integration

Trapezoidal numerical integration in MATLAB is done by the function called trapz.

Syntax

Z = trapz(Y) computes an approximation of the integral of Y via the trapezoidal method (with unit spacing). To compute the integral for spacing other than one, multiply Z by the spacing increment. Input Y can be complex. If Y is a vector, trapz(Y) is the integral of Y. If Y is a matrix, trapz(Y) is a row vector with the integral over each column.

Z = trapz(X,Y) computes the integral of Y with respect to X using trapezoidal integration. Inputs X and Y can be complex.


Example of trapz application

Let's compute the ∫0πsin(x)dx. The exact value of this integral is 2.

To approximate this numerically on a uniformly spaced grid, use

X = 0:pi/100:pi;

Y = sin(X);

Then use the trapz function:

Z = trapz(X,Y)

that produces:

Z = 1.9998

The result is not as accurate as the uniformly spaced grid [3].


Monday, August 6, 2012

NP Hard problem - explanation from Stephen Boyd

Students used to ask me about this - what is NP-hard problem and why is it important? The exact answer can easily be a topic of a monograph, but I have been looking for a simple yet accurate answer.


Well, NP stands for Non-deterministic Polynomial time. Simply speaking, an NP-complete problem cannot be solved in polynomial time in any known way. NP-Hard/NP-Complete is a way of showing that certain classes of problems are not solvable in realistic time.



Basically, a solution has to be testable in polynomial time. If that's the case, and a known NP problem can be solved using the given problem with modified input (an NP problem can be reduced to the given problem) then the problem is NP complete. NP-complete means the problem is at least as hard as any problem in NP.


On the other hand, there are polynomial-time problems. The class P consists of those problems that are solvable in polynomial time. For example, they could be solved in O(n^k) for some constant k, where n is the size of the input. Simply put, you can write a program that will run in reasonable time.

A decision problem is in P if there is a known polynomial-time algorithm to get that answer. A decision problem is in NP if there is a known polynomial-time algorithm for a non-deterministic machine to get the answer.

There is a good lecture notes about the NP-hard problems [PDF].

A simple and understandable explanation of the NP-hard problem that I like is given by Stephen Boyd:


This explanation is a bit watery, but basically boils down to the following. People identified a bunch of (computationally) very hard problems, to which nobody figured out a polynomial-time algorithm.

When the problem comes in, you measure the size of the data required to describe the problem. Then you look on the number of operations you have to do, and if you can bound that number of computations by polynomial, that's the polynomial-type problem.

There is a catalog of problems that are considered as computationally hard. You can call the problem as NP-hard if it is as hard as any of the problems from that catalog (e.g., travelling salesman).

Wednesday, October 12, 2011

Compressed sensing: notes and remarks

This short note is about the tutorial [1] on compressed sensing (CS) recently published in Optical Engineering journal. The tutorial introduces a mathematical framework that provide insight into how a high resolution image can be inferred from a relatively small number of measurements. Among other applications, such as IR imaging and compressing video sequences, astronomical applications [2] of CS are very attractive.


The idea of Compressed Sensing
The basic idea of CS [1] is that when the image of interest is very sparse or highly compressible in some basis, relatively few well-chosen observations suffice to reconstruct the most significant nonzero components. It can be also considered as projecting onto incoherent measurement ensembles [2]. Such an approach should be directly applied in the design of the detector. Devising an optical system that directly “measures” incoherent projections of the input image would provide a compression system that encodes in the analog domain.

Rather than measuring each pixel and then computing a compressed representation, CS suggests that we can measure a “compressed” representation directly.

The paper [1] provides a very illustrative example of searching the bright dot on a black background: instead of full comparison (N possible locations), the CS allows to do it in M=log2(N) binary measurements using binary masks.

The picture from the paper [1]


The key insight of CS is that, with slightly more than K well-chosen measurements, we can determine which coefficients of some basis are significant and accurately estimate their values.

A hardware example of Compressed sensing
An example of a CS imager is the rice single-pixel camera developed by Duarte et al [3,4]. This architecture uses only a single detector element to image a scene. A digital micromirror array is used to represent a pseudorandom binary array, and the scene of interest is then projected onto that array before the aggregate intensity of the projection is measured with a single detector.


Using Compressed Sensing in Astronomy
Astronomical images in many ways represent a good example of highly compressible data. An example provided in [2] is Joint Recovery of Multiple Observations. In [2], they considered a case that the data are made of N=100 images such that each image is a noise-less observation of the same sky area. The goal is to propose the decompression the set of observations in a joint recovery scheme. As the paper [2] shows, CS provides better visual and quantitative results: the recover SNR for CS is 46.8 dB, while for the JPEG2000 it is only 9.77 dB.

Remarks on using the Compressed Sensing in Adaptive optics
The possible application of the CS in AO can be for centroiding estimation. Indeed, the centroid image occupies only a small portion of the sensor. The multiple observations of the same centroid can lead to increased resolution in centroiding and, therefore, better overall performance of the AO system.

References:
[1] Rebecca M. Willett, Roummel F. Marcia, Jonathan M. Nichols, Compressed sensing for practical optical imaging systems: a tutorial. Optical Engineering 50(7), 072601 (July 2011).

[2] Jérôme Bobin, Jean-Luc Starck, and Roland Ottensamer, Compressed Sensing in Astronomy, IEEE JOURNAL OF SELECTED TOPICS IN SIGNAL PROCESSING, VOL. 2, NO. 5, OCTOBER 2008.

[3] M. F. Duarte, M. A. Davenport, D. Takhar, J. N. Laska, T. Sun, K. Kelly, and R. G. Baraniuk, “Single-pixel imaging via compressive sampling,” IEEE Signal Process. Mag. 25(2), 83–91 (2008).

[4] W. L. Chan, K. Charan, D. Takhar, K. F. Kelly, R. G. Baraniuk, and D. M. Mittleman, “A single-pixel terahertz imaging system based on compressed sensing,” Appl. Phys. Lett. 93, 121105 (2008).

Sunday, September 25, 2011

SPIE Optical Engineering and Applications 2011 - presentations from Astromentry section

Some interesting papers from the Astrometry section that held on Wednesday. This is not about the Adaptive optics, but still contains some interesting points.


 
1. Differention Tip-Tilt Jitter.

It is well known fact that the Tip/Tilt is the main source of distrubance in atmospherical seeing. Other distortions to consider are geometrical ones, like cushion/barrel.

Atmosphere is like a prism - it can displace the star position. Advantages of large telescopes are therefore reduced by CDAR noise.



Dynamic distortion calibration using a diffracting pupil: high-precision astrometry laboratory demonstration for exoplanet detection, . . . . . . [8151-29]


They want to create diffraction spikes. 





Saturday, September 17, 2011

Interesting astronomical papers from SPIE Optical Engineering and Applications conference 2011

More about papers from the SPIE conference; main section about the adatpvie optics was on Sunday, but some other interesting posters were in other days as well. 



Advancements in laser tomography implementation at the 6.5m MMT,  . . . .[8149-07]



The system on the MMT uses 5 LGS stars, 336 voice-coil actuators and they trying to use dynamics focus. The LGS they use is sodium beacon, and, as it is well known fact, the sodium LGS tends to elongate.


They capture everything on one CCD - this means that all of LGS on one CCD. They also use the WFS instrument for the NGS light from tip-tilt star (to sense the tip/tilt distortion).




Least-squares LTAO implementation uses SVD decompostition (modal decomposition) for tomographical reconstruction. Wind can be detected from multiple LGS beacons. They obtain then a tomographic matrix.


However, the problem with the SVD is computationally intensive algorithms.

The further challenges are presented on the slide above.


Wavefront control with SCExAO: concepts and first on-sky results,
Olivier Guyon, Frantz Martinache, Christophe Clergeon, Robert Russell, Subaru Telescope, National Astronomical Observatory of Japan (United States); . . . . . . . . . . . .[8149-08]


The paper presents a wavefront control on the Subaru telescope. They use phase induced amplitude apodizer (PIAA) - a novel concept that can be used for the coronography.

The PIAA is used for the redistribution of light without loss. They try to decrease the speackles using the PIAA.



A sensitivity comparison between the non-linear curvature wavefront
sensor and the Shack-Hartmann wavefront sensor in broadband, Mala Mateen,  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .[8149-09]

This was a really strange presentation. The promising title was ruined by poor presentation: out of slides it was impossible to understand the point.

They tried to compare Curvature WFS that measures:

\[ C = \frac{W_+ - W_-}{W_+ + W_-}

They observed Talbot effect:
Talbot imaging is a well-known effect that causes sinusoidal patterns to be reimaged by diffraction with characteristic period that varies inversely with both wavelength and the square of the spatial frequency. This effect is treated using the Fresnel diffraction integral for fields with sinusoidal ripples in amplitude or phase. The periodic nature is demonstrated and explained, and a sinusoidal approximation is made for the case where the phase or amplitude ripples are small, which allows direct determination of the field for arbitrary propagation distance.
[from the paper: Analysis of wavefront propagation using the Talbot effect
Ping Zhou and James H. Burge, Applied Optics, Vol. 49, Issue 28, pp. 5351-5359 (2010)       doi:10.1364/AO.49.005351 » View Full Text: Acrobat PDF (785 KB) ]





Image plane phase-shifting wavefront sensor for giant telescope
active and adaptive optics, François Hénault, Univ. de Nice Sophia Antipolis (France) . . . . . . . . . . . . . . . . . . . . . . . . . . . .[8149-10]

The paper is about phase shifting WFS, although the speaker was not very detailed in descriptions.



The thing is, they use it for making a cross-spectram measurements.


Friday, September 9, 2011

Finding a problem for the Research

In the July issue of IEEE Spectrum journal, there were a short but interesting article entitled "In Research, the Problem is the Problem". The author of it reflects about some issues of problem finding - that is, how to find a really worthy research question. There are no definite solution, of cource, but the article itself (one page only) is worth to read and think about. Here are some quotes from it (OCRed version is here).



A problem well stated is a problem half solved. -- Inventor Charles Franklin Kettering (1876-1958)



The solution of problem is not difficult; but finding a problem -- there's the rub. Engineering education is based on the presumption that there exists a predefined problem worthy of a solution.



Internet pioneer Craig Partridge recently sent around a list of open research problems in communications and networking, as well as a set of criteria for what constitutes a good problem. He offers some sensible guidelines for choosing research problems:

  • having a reasonable expectation of results
  • believing that someone will care about your results
  • others will be able to build upon them
  • ensuring that the problem is indeed open and under-explored.
All of this is easier said than done, however. Given any prospective problem, a search may reveal a plethora of previous work, but much of it will be hard to retrieve. On the other hand, if there is little or no previous work, maybe there's a reason no one is interested in this problem.



Real progress usually comes from a succession of incremental and progressive results, as opposed to those that feature only variations on a problem's theme.



At Bell Labs, the mathematician Richard Hamming used to divide his fellow researchers into two groups: those who worked behind closed doors and those whose doors were always open. The closed-door people were more focused and worked harder to produce good immediate results, but they failed in the long term.



Today I think we can take the open or closed door as a metaphor for researchers who are actively connected and those who are not. And just as there may be a right amount of networking, there may also be a right amount of reading, as opposed to writing. Hamming observed that some people spent all their time in the library but never produced any original results, while others wrote furiously but were relatively ignorant of the relevant literature.

Tuesday, August 30, 2011

Highlights of the SPIE Optical Engineering + Applications Conference at San Diego, CA, 2011


Most of interesting oral presentations was on Sunday, where the astronomical adaptive optics was discussed. Here are some remarks on them from the section Astronomical Adaptive Optics Systems and Applications V.


Integration and test of the Gemini Planet Imager . . . . . . .[8149-01]
For the extreme AO, they plan to achieve 2-4 arcseconds of angular resolution. Since it is a Cassegrain focus, the instruments must be located under the focus and move with the telescope.
There are some interesting lessons they learned from the WFS:
  • small subapertures make it hard to align;
  • mount of the camera is hard to align;
The lenslet size is 63 micrometers that introduces a lot of diffraction effects.

The controller they use is commercial closed black-box (Fourier, predictive controller).
The WFS used is Shack-Hartmann quadcell. WFS noise is 4-5 e- at 1 KHz speed.



The TMTracer: a modeling tool for the TMT alignment and phasing
system, Piotr K. Piatrou, Gary A. Chanan, Univ. of California, Irvine (United States) . . . .[8149-03]

This is about the simulator of the TMT parts written by Piotr K. Piatrou on FORTRAN 95. No diffraction effects, only ray tracing.

This is for alignment and phase sensing of the telescope mirrors. The control of the wavefront is LS tomography - filtration of commands directly to DM. This is due to huge amount of data.
Observability must be computed theoretically, then the SVD decomposition is used.



Athermal design of the optical tube assemblies for the ESO VLT Four Laser Guide Star Facility, Rens Henselmans, David Nijkerk, Martin Lemmen, Fred Kamphues, TNO Science and Industry (Netherlands) . . . .[8149-04]

Interesting speech about the design of LGS tube, they actually use it for VLT with 4 GS for lambda=589 nm and power 25 W.
Optical design of the LGS tube is classical Gallilean 20x beamer expander. Athermal design was a primary goal. Laser absorption is estimated as 0.1 ... 1% for 25 W which is pretty much. They are making a big tube from invar (steel alloy) to expand a light beam - not from caron since it is very expensive. L2 Lense in their design is 38 cm in diameter.


Overview of the control strategies for the TMT alignment and phasing system, Piotr K. Piatrou, Gary A. Chanan, Univ. of California, Irvine (United States) . . . . . . . . .[8149-05]

The main goal here is to automatically control alignment of AO parts on the TMT. The multidirectional tomography is the mainstream approach for TMT alignment.The PAS (alignment and phasing system) is n open-loop system without accounting for the dynamics.

This is for the alignment only. The control is brute-force LS tomography because of huge amount of data. They have 33GB for SVD, and therefore use complexity reduction methods. For instance, projection mehtod like Oa = s -> \[ P\dagger O a = P\dagger a \]

In the case of TMT, I think, it is possbile to nglect the dynamics of the system completely and just assume that the system is static. For low and medium frequencies it will probbly work well. That cruel algorithm (just throw the command to DM) explains the 2*opd coefficient 2.

The quasi-continuous part for the control.




Sunday, August 28, 2011

Manufacturing and using the continuous-facesheet deformable mirrors

There are some notes from SPIE Optical Engineering + Applications poster discussions and presentations about deformable mirrors.



It was interesting to know that Xinetics still uses very strong actuators that can actually break the mirror even in the presence of electrical protection. Some say they just do not want to upgrade their technology as NASA buys from them. Therefore, if there are very powerful actuators, the beackage of a mirror is possible. Other, like Gleb Vdovin from OKO Technologies, use soft actuators (piezoelectric ones) and the force of them is not enough to break the mirror.





How to attach an actuator to a Deformable Mirror?

Simple answer: using epoxy glue. Surprisingly, even after many days of work epoxy glue still holds actuators very well. Moreover, there were special tests: for instance, one can write a program (DMKILL) that throws random "0" and "+max" voltages on the mirror. It was reported that the first actuator broken down after at least 10 days (!) of constant work in such a regimen.



In the case of broken actuator, many people suggested just to throw it away as a loss of one actuator does not effects the rest too badly.





Main problem is Tip\Tilt

Tip and Tilt are the major sources of problems caused by the atmospheric turbulence. An impact of the higher aberrations falls very quickly. The correction is therefore required for the tip/tilt.

For this, a WFS with Zernike fitting can be helpful.



However, as Guan Ming Dai notes in his paper "Comparison of wavefront reconstructions with Zernike polynomials and Fourier transforms." [J Refract Surg. 2006 Nov;22(9):943-8.],
Fourier full reconstruction was more accurate than Zernike reconstruction from the 6th to the 10th orders for low-to-moderate noise levels. Fourier reconstruction was found to be approximately 100 times faster than Zernike reconstruction. Fourier reconstruction always makes optimal use of information. For Zernike reconstruction, however, the optimal number of orders must be chosen manually.



Wednesday, August 24, 2011

Interesting posters from SPIE Optical Engineering + Applications San Diego, CA, 2011

  1. Na variability and LGS elongation: impact on wavefront error, Katharine J. Jones, WBAO Consultant Group (United States). . . . . . . . . . . . . . . . . . . .[8149-14]
  2. MT_RAYOR: a versatile raytracing tool for x-ray telescopes, Niels Jørgen S.

    Westergaard, Technical Univ. of Denmark (Denmark) . . . . . . . . . . . . . [8147-64] <---- this simulator is actually written on Yorick
  3. A hardware implementation of nonlinear correlation filters, Saul Martinez-

    Diaz, Hugo Castañeda Giron, Instituto Tecnológico de La Paz (Mexico)[8135-49] <--- the poster actually is about morphological filtres implemented in hardware.
  4. Development of the visual encryption device using higher-order

    birefringence, Hiroyuki Kowa, Takanori Murana, Kentaro Iwami, Norihiro

    Umeda, Tokyo Univ. of Agriculture and Technology (Japan); Mitsuo Tsukiji,

    Uniopt Co. Ltd. (Japan); Atsuo Takayanagi, Tokyo Univ. of Agriculture and

    Technology (Japan) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [8134-32]
  5. Enhancement of the accuracy of the astronomical measurements carried

    on the wide-field astronomical image data, Martin Rerábek, Petr Páta, Czech

    Technical Univ. in Prague (Czech Republic) . . . . . . . . . . . . . . . . . . . . . [8135-58]
  6. Astronomical telescope with holographic primary objective, Thomas D.

    Ditto, 3DeWitt LLC (United States) . . . . . . . . . . . . . . . . . . . . . . . . . . . . [8146-40]
  7. Calibration of the AVHRR near-infrared (0.86 μm) channel at the Dome

    C site, Sirish Uprety, Changyong Cao, National Oceanic and Atmospheric

    Administration (United States). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [8153-74]













Wednesday, August 17, 2011

A note about Greenwood frequency

Greenwood frequency\cite{greenwoodbandwidth} is a single parameter that can represent the entire spectrum for adaptive optics. It is a measure of the characteristic frequency of the tilt of atmospheric turbulence\cite{tysonprinciplesbook}, and is expressed by Tyler\cite{tyler1994bandwidth} for the G-tilt:









where $v_w(z)$ is a wind velocity, and $\beta$ is the zenith angle. The Greenwood frequency can be associated with turbulence temporal error. The atmospheric turbulence conjugation process can be limited by temporal deficiencies as well as spatial ones\cite{karr1991temporal}. Assuming perfect spatial correction, Greenwood\cite{greenwoodbandwidth} showed that the variance of the corrected wavefront due to temporal limits is given by: $$\sigma^2_{temp} = \int_{0}^{\infty} |1 - H(f,f_c)|^2 P(f) df$$ where the $P(f)$ is the disturbance power spectrum\cite{tysonprinciplesbook}. The higher-order wavefront variance due to temporal constraints is $$\sigma_{temp}^2 = [\frac{f_G}{f_{3~dB}}]^{5/3}$$ where the $f_G$ is the Greenwood frequency.





Greenwood frequency as an estimation of a controller's bandwidth

The required frequency bandwidth of the control system is called the Greenwood frequency\cite{greenwoodbandwidth}. An adaptive optics system with a closed-loop servo response should reject most of the phase fluctuations. Greenwood\cite{greenwoodbandwidth} calculated the characteristic frequency $f_G$ as follows:











where $\beta$ is the zenith angle, $v_w$ is wind velocity. In the case of a constant wind and a single turbulent layer, the Greenwood frequency $f_G$ can be approximated by: $$f_G = 0.426 \frac{v_w}{r_0},$$ where $v_w$ as the velocity of the wind in meters/sec and $r_0$ is the Fried parameter. Greenwood\cite{greenwoodbandwidth} determined the required bandwidth, $f_G$ (the Greenwood frequency), for full correction by assuming a system in which the remaining aberrations were due to finite bandwidth of the control system\cite{saha2010aperture}. Greenwood derived the mean square residual wavefront error as a function of servo-loop bandwidth \textit{for a first order controller}, which is given by:







where $f_c$ is the frequency at which the variance of the residual wavefront error is half the variance of the input wavefront, known as 3 db closed-loop bandwidth of the wavefront compensator, and $f_G$ the required bandwidth\cite{saha2010aperture}. It must be noted that the required \textit{bandwidth for adaptive optics does not depend on height}, but instead is proportional to $v_w /r_0$ , which is in turn proportional to $\lambda^{-6/5}$. If the turbulent layer moves at a speed of 10 m/s, the closed loop bandwidth for $r_0 \approx 11$ cm, in the optical band (550 nm) is around 39 Hz\cite{saha2010aperture}.



For most cases of interest, the Greenwood frequency of the atmosphere is in the range of tens to hundreds of Hertz. Beland and Krause-Polstorff\cite{greenwoodfreqvariation} present measurements that show how the Greenwood frequency can vary between sites. Mt. Haleakala in Maui, Hawaii, has an average Greenwood frequency of 20 Hz. For strong winds and ultraviolet wavelengths, the Greenwood frequency can reach 600 Hz. The system bandwidth on bright guide stars is, in most cases, several times larger than the Greenwood frequency.





\begin{thebibliography}{1}

\bibitem{greenwoodbandwidth} D.~P. Greenwood.

\newblock
Bandwidth specification for adaptive optics systems.

\newblock
{\em J. Opt. Soc. Am.}, 67:390--93, 1977.



\bibitem
{tysonprinciplesbook} R.~Tyson.

\newblock
Principles of adaptive optics. \newblock 2010.



\bibitem{tyler1994bandwidth} G.A. Tyler.

\newblock
Bandwidth considerations for tracking through turbulence.

\newblock {\em JOSA A}, 11(1):358--367, 1994.



\bibitem
{karr1991temporal} T.J. Karr.

\newblock Temporal response of atmospheric turbulence compensation.

\newblock
{\em Applied optics}, 30(4):363--364, 1991.



\bibitem{saha2010aperture} S.K. Saha.

\newblock Aperture synthesis: Methods and applications to optical astronomy.

\newblock
2010.



\bibitem{greenwoodfreqvariation} R.~Beland and J.~Krause-Polstorff.

\newblock Variation of greenwood frequency measurements under different meteorological conditions.

\newblock
In {\em Proc. Laser Guide Star Adaptive Optics Workshop 1, 289. Albuquerque, NM: U. S. Air Force Phillips Laboratory}, 1992.

\end{thebibliography}

Monday, August 15, 2011

A laser from a living cell

In the OPN journal there was published a short note about the laser from a living cell. The cell was genetically engineered to produce a green-glowing jellyfish protein. Then the cell was placed between two reflectors.



From To Imaging, and Beyond!




In such a setup the cell acts as the laser's gain medium. When pumped with a brief burst of blue light, the proteins fluoresced, generating light that bounced back and forth between the reflectors, gaming more energy with each pass through the cell.


By the way, from the OPN journal again, the table of lasers and their power:



Quite nice.

Wednesday, August 3, 2011

Simulink tricks: multiple plots / two or more inputs on Scope

In the Simulink's scope block, which is commonly used to display the results of the simulation, has only one input port. But sometimes we want to display more than one signal on the same axis. There are several tricks to display multiple plots (two or more inputs) on the Scope.


Trick 1: use Mux block

Use the Mux block from the Signal Routing palette:

to merge two signals in one and connect them to Scope. Here is an example scheme:




Trick 2: use Vector concatenate block

Another solution is to use the Vector Concatenate block from the Signal Routing palette:

This trick will collect all the signals to be displayed, and then to connect the output from the vector concatenate block to the one input port of the Scope. In matrix case, of course, use Matrix concatenate. The example of schematics is presented below:



The result
Simulink will automatically highlight each signal by a different colour, as shown below:

Thursday, June 30, 2011

Books on Kalman Filter

Here is small note about the Kalman and Particle filters. The list and comment reflect only my humble point of view: I'm an engineer who does not particularly like terse theoretical-orientated volumes.

Optimal State Estimate by Dan Simon
A very comprehensive book and, which is more important, it uses a bottom-up approach that enables readers to master the material rather quickly. Dan Simon's book is the best and the most suitable for self-study. Explanations are concise and straightforward. This book relates control theory elegantly. The author uses well laid out algorithmic approaches, suitable for programming, and examples to explain the details and show the complexities in action.
You will find all estimation topics in one book: Kalman filter, Unscented Kalman (UKF), Extended Kalman (EKF) and a very good explanation of Particle filtering (PF).

Moreover, the author has a website with a lot of MATLAB code for the examples used in book. This is a great help in terms of understanding of the subject, as most of examples are very insightful.


Introduction to Random Signals and Applied Kalman Filtering by Brown and Hwang
The book is easy to read and easy to follow: it starts from the very detailed explanation of the background needed for the Kalman filter. Obviously, the authors had an extensive teaching experience. The explanation of the Discrete Kalman Filter is one of the best I ever found. The extended KF and some implementation issues (UDU filter, sequential estimation) are not covered as well as other topics.

One should admit, however, that starting from the Chapter 6, the authors evidently exhausted and the text started to be more and more terse. The chapter about Kalman smoothing I could hardly translate to human language - better to use Dan Simon book.



Advanced Kalman Filtering, Least Squares and Modelling: A practical Handbook by Bruce Gibbs
The book is very terse in terms of explanations, and one should read it only as a reference, with a good background in Kalman filtering. Advanced topics, such as Particle Filter and Unscented Kalman, are covered in a very short manner and not very insightful. This is a handbook after all and not the book for the self-study. However, the book provides a lot of in-depth information and insight into various areas not found elsewhere.
This will be most useful for somebody with a strong mathematical background, particularly in linear algebra, who is looking for a comprehensive understanding and the best solution for a particular application.
Overall: a good reference, but not very helpful in terms of explanation.

Sunday, June 26, 2011

Notes on the structure of the scientific article

Here are some notes about the structure of the scientific papers and some helpfull tips. Basically, any scientific paper can be divided on:
  • abstract
  • introduction
  • methods (mathematical formulation)
  • results
  • discussion
  • conclusion
  • acknowledgements

Title
The title should be short and unambiguous, yet be an adequate description of the work. A general rule-of-thumb is that the title should contain the key words describing the work presented. Remember that the title becomes the basis for most on-line computer searches - if your title is insufficient, few people will find or read your paper.


Abstract

Once you have the completed abstract, check to make sure that the information in the abstract completely agrees with what is written in the paper. Confirm that all the information appearing the abstract actually appears in the body of the paper.

A well-prepared abstract enables the reader to identify the basic content of a document quickly and accurately. The abstract concisely states the principal objectives and scope of the investigation where these are not obvious from the title. The abstract must be concise; most journals specify a length, typically not exceeding 250 words. If you can convey the essential details of the paper in 100 words, do not use 200.


Introduction

The introduction defines the subject and must: outline the scientific objectives for the research performed and give the reader sufficient background to understand the rest of the report.

A good introduction will answer several questions:

1. Why was this study performed? Answers to this question may be derived from observations of nature or from the literature.

2. What knowledge already exists about this subject? That is review of the literature, showing the historical development of an idea and including the confirmations, conflicts, and gaps in existing knowledge.

3. What is the specific purpose of the study? The specific hypotheses and experimental design pertinent to investigating the topic should be described.

4. What is the Novelty of this paper? An important function of the introduction is to establish the significance of your current work: Why was there a need to conduct the study? Having introduced the pertinent literature and demonstrated the need for the current study, you should state clearly the scope and objectives.

Fundamental questions to answer here include:

  • Do your results provide answers to your testable hypotheses? If so, how do you interpret your findings?
  • Do your findings agree with what others have shown? If not, do they suggest an alternative explanation or perhaps a unforseen design flaw in your experiment (or theirs?)
  • Given your conclusions, what is our new understanding of the problem you investigated and outlined in the Introduction?
  • If warranted, what would be the next step in your study, e.g., what experiments would you do next?


Methods
Materials and methods used in the experiments should be reported. What equipment was used, what is the mathematics that describes the process?
However, it is still necessary to describe special pieces of equipment and the general theory of the assays used. This can usually be done in a short paragraph, possibly along with a drawing of the experimental apparatus.


Results

  1. All scientific names (genus and species) must be italicized. (Underlining indicates italics in a typed paper.)
  2. Use the metric system of measurements. Abbreviations of units are used without a following period.
  3. Be aware that the word data is plural while datum is singular. This affects the choice of a correct verb. The word species is used both as a singular and as a plural.
  4. Numbers should be written as numerals when they are greater than ten or when they are associated with measurements; for example, 6 mm or 2 g but two explanations of six factors. When one list includes numbers over and under ten, all numbers in the list may be expressed as numerals; for example, 17 sunfish, 13 bass, and 2 trout. Never start a sentence with numerals. Spell all numbers beginning sentences.
  5. Be sure to divide paragraphs correctly and to use starting and ending sentences that indicate the purpose of the paragraph. A report or a section of a report should not be one long paragraph.
  6. Every sentence must have a subject and a verb.
  7. Avoid using the first person, I or we, in writing. Keep your writing impersonal, in the third person. Instead of saying, "We weighed the frogs and put them in a glass jar," write, "The frogs were weighed and put in a glass jar."
  8. Avoid the use of slang and the overuse of contractions.
  9. Be consistent in the use of tense throughout a paragraph--do not switch between past and present. It is best to use past tense.
  10. Be sure that pronouns refer to antecedents. For example, in the statement, "Sometimes cecropia caterpillars are in cherry trees but they are hard to find," does "they" refer to caterpillars or trees?
After writing a report, read it over, watching especially for lack of precision and for ambiguity. Each sentence should present a clear message.



Conclusion
Introductions and conclusions can be the most difficult parts of papers to write. While the body is often easier to write, it needs a frame around it. An introduction and conclusion frame your thoughts and bridge your ideas for the reader.

Your conclusion should make your readers glad they read your paper. Your conclusion gives your reader something to take away that will help them see things differently or appreciate your topic in personally relevant ways. It can suggest broader implications that will not only interest your reader, but also enrich your reader's life in some way.

Generally, three questions in the conclusion should be addressed:

1. What the problem was addressed?
2. What are results?
3. So what?

Play the "So What" Game. If you're stuck and feel like your conclusion isn't saying anything new or interesting, ask a friend to read it with you. Whenever you make a statement from your conclusion, ask the friend to say, "So what?" or "Why should anybody care?" Then ponder that question and answer it. Here's how it might go:

You: Basically, I'm just saying that education was important to Douglass.

Friend: So what?

You: Well, it was important because it was a key to him feeling like a free and equal citizen.

Friend: Why should anybody care?

You: That's important because plantation owners tried to keep slaves from being educated so that they could maintain control. When Douglass obtained an education, he undermined that control personally.

You can also use this strategy on your own, asking yourself "So What?" as you develop your ideas or your draft.

Synthesize, don't summarize. Include a brief summary of the paper's main points, but don't simply repeat things that were in your paper. Instead, show your reader how the points you made and the support and examples you used fit together.

Propose a course of action, a solution to an issue, or questions for further study. This can redirect your reader's thought process and help her to apply your info and ideas to her own life or to see the broader implications.

Looking to the future: Looking to the future can emphasize the importance of your paper or redirect the readers' thought process. It may help them apply the new information to their lives or see things more globally.


Monday, June 6, 2011

Books about Adaptive Optics

Here is a small list of books on Adaptive optics. There are not many of them since the subject is quite specific and requires wide and diverce background.

Adaptive Optics for Astronomical Telescopes (Oxford Series in Optical \& Imaging Sciences) by John Hardy
Hardy was a pioneer in adaptive optics and in the 1970s he built the first system capable of compensating the turbulence of a large astronomical telescope at visible wavelengths.

The book is very comprehensive, with an excellent bibliography and outstanding illustrations. The text is informative and consistent, with strong points in atmosphere turbulence and deformable mirrors. As a minor issues I must mention that the control part of adaptive optics is covered less deeply, but enough for the first-time reader. Despite of its age, the book gives all necessary background to enter to adaptive optics field.

The book by Hardy is by far The Best book in adaptive optics.

John W. Hardy, Adaptive optics for astronomical telescopes, Oxford University Press, USA, 1998.


Numerical Simulation of Optical Wave Propagation With Examples in MATLAB, by Jason Schmidt
The book presents the latest advances in numerical simulations of optical wave propagations in turbulent media. The book is clearly written and abundant of excellent examples in MATLAB giving to the reader a lot of step-by-step introductions as well as understanding of the waves propagation. The writing style is very engaging.

However, the Chapter 9 is slightly denser than others (I think it could be split on two different chapters). The operators notations used in Chapter 6 sometimes are more difficult to follow than conventional expressions. But those are minor issues that do not affect the material of the book.

Overall, the material of the book and the MATLAB code present a solid basis for the numerical simulations. Carefully selected bibliography of the book allows to use it as an excellent reference.


Jason D. Schmidt, Numerical Simulation of Optical Wave Propagation, With Examples in Matlab, Society of Photo-Optical Instrumentation Engineers, 2010.



Adaptive Optics in Astronomy by Francois Roddier
This is a very good example of how one should NOT write a book. This is not even a book but just a draft of several conference proceedings meshed together. There is no transition between chapters, the writing skills of different authors are very different and it is quite annoying.

For instance, in chapter about numerical simulations you will find NOTHING about how to really simulate the AO systems: no sinlge formula or plot. Chapter about ``theoretical'' background is written in a manner that there actually is a solid theory behind it - and most formulas are starting with numercial coefficient, which is improssible to get theoretically.

The second part of book is just a outdate garbage: stories of how the author built telescopes, with unnecessary detailed information that is useless now.

Don't waste your time on it.


Adaptive optics handbook by R.Tyson
The following books is by R. Tyson. Personally, I think that reading books from Tyson is mostly waste of time. He is like bakery that produces books as they are cakes. Very few useful information. More pity is that Tyson is a non-stop-backery than stamps and stamps books, one worse than other.

Monday, May 16, 2011

A note on Waffle Modes

Wavefront sensors are insensitive to certain phase aberration patterns called waffle. A Shack-Hartmann sensor is proven to suffer from blind or null modes: wavefront functions that can yield zero or very small response in the SH WFS output[1].

The commonly-used square Fried geometry[2] sensing in most Shack-Hartmann-based adaptive optics (AO) systems is insensitive to a checkerboard-like pattern of phase error called waffle. This zero mean slope phase error is low over one set of WFS sub-apertures arranged as the black squares of a checkerboard, and high over the white squares.

Waffle mode is essentially a repeated astigmatic pattern at the period of the SH sampling over the entire aperture. This wavefront has zero average slope over every sub-aperture and hence produces zero SH WFS output. The illustration of the waffle pattern on the DM is in Fig. 1.

Figure 1: Waffle mode on the DM [the picture from[3]]


Efforts have been made to understand how to control this and other ``blind'' reconstructor modes[1,4,5]. Advances in wave front reconstruction approaches have improved AO system performance considerably. Many physical processes cause the waffle: misregistration, high noise levels on the photosensor of WFS and so on.

Atmospheric turbulence and the Waffle modes

The initial uncertainty of atmospheric phase[1] is given by Kolmogorov statistics[6,7]. The atmosphere is unlikely to contain high spatial frequency components relative to low spatial frequency ones. Atmospheric turbulence has the form of a fractal and has much more power at large spatial scales so that the idea that the atmospheric wavefront can have big swings between adjacent phase points is physically unrealistic. This acts fortuitously to suppress waffle behaviour, which is a high spatial frequency behaviour.

Waffle modes during the Wavefront Sensing

The first step is to define the phase differences in terms of the phase measurements. Most gradient and curvature wavefront sensors do not sense all possible modes. For instance, the Fried geometry cannot measure the so-called Waffle mode. The Waffle mode occurs when the actuators are moved in a checkerboard pattern: all white squares change position while the black squares remain stationary. This pattern can build up over time, it is reduced by using different actuator geometries or filtering the control signals so as suppress this mode.

The curvature WFS, is not sensitive to waffle mode error, although it has its own particular null space. Curvature sensors are typically not used for AO systems with more sensing channels because of their noise propagation properties[8].

We stress here that waffle mode error does not depend fundamentally on the actuator location and geometry: it only depends on the sensor geometry[9].

Waffle modes in Deformable Mirrors

The best DMs that we make use a quasi-hex geometry, which reduces waffle pattern noise. In the continuous-facesheet mirrors, the actuators push and pull on the surface. Since the surface in continuous, there is some mechanical crosstalk from one actuator to the next one - this is so-called influence function. But that can be controlled through software within the control computer. Because most DM have regular arrays of actuators, either square or hexagonal geometries, the alternate pushing and pulling of adjacent actuators can impart a patterned surface that resembles a waffle. The ``waffle mode'' can appear in images of regular patter, which acts an an unwanted diffraction grating[10].

Removing the waffle modes

There is a weighting approach proposed by Gavel[1] that will actually change the mode space structure. We introduce an actuator weighting, but instead of using a scalar regularisation parameter we use a positive-definite matrix. An a-priori statistical information concerning the quantities to be determined and the measurement noise can be used to set the weighting matrices in the cost function terms.

The technique penalises all local waffle behaviour using the weighting matrix. It was found[1] that only a modification of the cost function by including a penalty term on the actuators will actually modify the mode space. With a suitable weighting matrix on the actuators, waffle behaviour can be sorted out into modes that have the least influence in the reconstruction matrix, thus suppressing waffle in the wavefront solutions.

The problem is that when the waffle modes go unsensed, they are not corrected by the DM and can accumulate within the closed-loop operation of the system. The accumulation of waffle modes leads to serious performance problems. The simplest way to correct them is that the adaptive-optics operator opens the feedback loop of the system in order to clear the DM commands and alleviate the waffle.

The waffle pattern accumulates in a closed-loop feedback system because the sensor cannot sense the mode for compensation. Spatially filtering the DM commands gives the option to maintain a conventional reconstructor while still having the ability to mitigate the waffle mode when it occurs[3]. In those experiments authors used a leaky integrator.

The paper[3] analyses a technique of sensing the waffle mode in the deformable mirror commands and applying a spatial filter to those commands in order to mitigate for the waffle mode. Directly spatially filtering the deformable mirror commands gives the benefit of maintaining the reconstruction of high frequency phase of interest while having the ability to alleviate for the waffle-like pattern when it arises[3].

This paper[3] will present a technique that only alleviates for the waffle when it is detected and does not effect the reconstruction of the phase when the mode has not accumulated to a degree that causes degradation in the performance of the system.


Bibliography


1
D.T. Gavel.
Suppressing anomalous localized waffle behavior in least-squares wavefront reconstructors.
4839:972, 2003.
2
D.L. Fried.
Least-square fitting a wave-front distortion estimate to an array of phase-difference measurements.
JOSA, 67(3):370-375, 1977.
3
K.P. Vitayaudom, D.J. Sanchez, D.W. Oesch, P.R. Kelly, C.M. Tewksbury-Christle, and J.C. Smith.
Dynamic spatial filtering of deformable mirror commands for mitigation of the waffle mode.
In SPIE Optics & Photonics Conference, Advanced Wavefront Control: Methods, Devices, and Applications VII, Vol. 7466: 746609, 2009.
4
L.A. Poyneer.
Advanced techniques for Fourier transform wavefront reconstruction.
4839:1023, 2003.
5
R.B. Makidon, A. Sivaramakrishnan, L.C. Roberts Jr, B.R. Oppenheimer, and J.R. Graham.
Waffle mode error in the AEOS adaptive optics point-spread function.
4860:315, 2003.
6
A.N. Kolmogorov.
Dissipation of energy in the locally isotropic turbulence.
Proceedings: Mathematical and Physical Sciences, 434(1890):15-17, 1991.
7
A.N. Kolmogorov.
The local structure of turbulence in incompressible viscous fluid for very large Reynolds numbers.
Proceedings: Mathematical and Physical Sciences, 434(1890):9-13, 1991.
8
A. Glindemann, S. Hippler, T. Berkefeld, and W. Hackenberg.
Adaptive optics on large telescopes.
Experimental Astronomy, 10(1):5-47, 2000.
9
R. B. Makidon, A. Sivaramakrishnan, M. D. Perrin, L. C. Roberts, Jr., B. R. Oppenheimer, R. Soummer, and J. R. Graham.
An analysis of fundamental waffle mode in early aeos adaptive optics images.
The Publications of the Astronomical Society of the Pacific, 117:831-846, August 2005.
10
R.K. Tyson.
Adaptive optics engineering handbook.
CRC Press, 2000.

Monday, May 9, 2011

A note on speed comparison of wavefront reconstruction approaches

The two main reconstruction geometries are namely Hudgin and Fried. In the Hudgin geometry, gradients are the first differences between neighbouring actuators\cite{poyneer2003advanced}. In the Fried geometry, gradients are the average of the two first-differences on a square. Many adaptive optics systems use vector-matrix-multiply (VMM) reconstructors to convert gradient measurements to wavefront phase estimates. The computation time of the reconstruction using the VMM method scales as $O(n^2)$\cite{PoyneerFastFFTreconWFR}.

The reconstruction of the wavefront by means of the FFT was proposed by Freischlad and Koliopoulos\cite{freischlad1985wavefront} for square apertures on the Hudgin geometry. In a further paper\cite{FreischladFFTreconWFR} the authors derived methods for additional geometries, including the Fried geometry, which uses one Shack-Hartmann (SH) sensor. Freischlad also considered the case of small circular apertures\cite{freischladwfrfft} and the boundary problem was identified.


Computational speed comparison
The computational speed of Hudgin-FT and Fried-FT are limited only by the FFT\cite{poyneer2003advanced}. The extra processing to solve the boundary problem is of a lower order of growth computationally. Therefore FFT implementations have computational costs that scale as $O(n \log n)$. However, the implementation of Fried-FT requires potentially 2 times as much total computation as the Hudgin-FT. For the $64 \times 64$ grid, the FFT can be calculated on currently available systems in around 1 ms\cite{poyneer2003advanced}. If $N$ is a power of two the spatial filter, operations can be implemented with FFT's very efficiently. The computational requirements then scale as $O( N^2 log_2 N )$ rather than as $O( N^4 )$ in the direct vector-matrix multiplication approach. The modified Hudgin takes half as much computation as the Fried geometry model\cite{poyneer2003advanced}.


Comparison of FFT WFR and Zernike reconstruction speed

A very interesting paper appeared in the Journal of Refract Surgery\cite{dai2006comparison}. A comparison between Fourier and Zernike reconstructions was performed. In the paper\cite{dai2006comparison}, noise-free random wavefronts were simulated with up to the 15th order of Zernike polynomials. Fourier full reconstruction was more accurate than Zernike reconstruction from the 6th to the 10th orders for low-to-moderate noise levels. Fourier reconstruction was found to be approximately \textbf{100 times faster than Zernike reconstruction}. For Zernike reconstruction, however, the optimal number of orders must be chosen manually. The optimal Zernike order for Zernike reconstruction is lower for smaller pupils than larger pupils. The paper\cite{dai2006comparison} concludes that the FFT WFR is faster and more accurate than Zernike reconstruction, makes optimal use of slope information, and better represents ocular aberrations of highly aberrated eyes.


Noise propagation

Analysis and simulation show that for apertures just smaller than the square reconstruction grid (DFT case), the noise propagations of the FT methods are favourable. For the Hudgin geometry, the noise propagator grows with $O(\ln n)$. For the Fried geometry, the noise propagator is best-fit by a curve that is quadratic in the number of actuators, or $O(\ln^2 n)$. For fixed power-of-two sized grids (required to obtain the speed of the FFT for all aperture sizes) the noise propagator becomes worse when the aperture was much smaller than the grid\cite{poyneer2003advanced}.


Shack-Hartmann sensor gain

The Shack-Hartmann WFS produces a measurement which deviates from the exact wavefront slope. The exact shape of this curve depends on number of pixels used per sub-aperture and the centroid computation method (see \cite{hardyAObook} section 5.3.1 for a representative set of response curves). The most important feature of the response curve is that even within the linear response range, the gain of the sensor is not unity\cite{poyneer2003advanced}. This gain is important in the open-loop: in a closed loop this problem in mitigated by the overall control loop gain, which can be adjusted instead.

References:

\begin{thebibliography}{1}  \bibitem{poyneer2003advanced} L.A. Poyneer. \newblock {Advanced techniques for Fourier transform wavefront reconstruction}. \newblock In {\em Proceedings of SPIE}, volume 4839, page 1023, 2003.  \bibitem{PoyneerFastFFTreconWFR} Lisa~A. Poyneer, Donald~T. Gavel, and James~M. Brase. \newblock Fast wave-front reconstruction in large adaptive optics systems with   use of the fourier transform. \newblock {\em J. Opt. Soc. Am. A}, 19(10):2100--2111, Oct 2002.  \bibitem{freischlad1985wavefront} K.~Freischlad and C.L. Koliopoulos. \newblock {Wavefront reconstruction from noisy slope or difference data using   the discrete Fourier transform}. \newblock 551:74--80, 1985.  \bibitem{FreischladFFTreconWFR} Klaus~R. Freischlad and Chris~L. Koliopoulos. \newblock Modal estimation of a wave front from difference measurements using   the discrete fourier transform. \newblock {\em J. Opt. Soc. Am. A}, 3(11):1852--1861, Nov 1986.  \bibitem{freischladwfrfft} Klaus~R. Freischlad. \newblock Wave-front integration from difference data. \newblock {\em Interferometry: Techniques and Analysis}, 1755(1):212--218,   1993.  \bibitem{dai2006comparison} G.~Dai. \newblock {Comparison of wavefront reconstructions with Zernike polynomials and   Fourier transforms.} \newblock {\em Journal of refractive surgery}, 22(9):943--948, 2006.  \bibitem{hardyAObook} John~W. Hardy. \newblock {\em {Adaptive optics for astronomical telescopes}}. \newblock Oxford University Press, USA, 1998.  \end{thebibliography}


Related Posts Plugin for WordPress, Blogger...